MAGNETIC AMPLIFIER TRAINER KIT (SERIES & PARALLEL)

Home Electronics Instrumentation & Control Lab MAGNETIC AMPLIFIER TRAINER KIT (SERIES & PARALLEL)
MAGNETIC AMPLIFIER TRAINER KIT (SERIES & PARALLEL)

MAGNETIC AMPLIFIER TRAINER KIT (SERIES & PARALLEL)

Category: Electronics

Model No: IE-CL-17

Amplification is the control of a larger output quantity by the variation of a smaller input quantity. Such amplification can be performed by saturable reactors connected either in series or in parallel.. This set up consists two such reactors, AC and DC power supply, two meters for load and control currents and a fixed value RL. The set up to study the characteristics of series - parallel connected magnetic amplifier, has two identical gate and control windings wound upon split deltamax cores, which are placed together to form two saturable reactors. 

A compensation winding is wound between the gate windings and connected with control windings for proper phase correction. Sockets are given to connect the amplifier gate windings in series parallel mode, while control windings are joined together with compensation windings internally. A control bias battery in form of regulated DC 0-3Volt supply with a DC mA meter to read IC, and current limit resistance is provided to study control and saturation characteristics.The polarity of DC current applied to control winding may be changed with polarity selector. Two fixed value (20 and 100 OHM) RL are given to study the effect upon transfer characteristics, with stepped down fixed AC supply with an AC ammeter to read load current IL.

Product Description

A compensation winding is wound between the gate windings and connected with control windings for proper phase correction. Sockets are given to connect the amplifier gate windings in series parallel mode, while control windings are joined together with compensation windings internally. A control bias battery in form of regulated DC 0-3Volt supply with a DC mA meter to read IC, and current limit resistance is provided to study control and saturation characteristics.The polarity of DC current applied to control winding may be changed with polarity selector. Two fixed value (20 and 100 OHM) RL are given to study the effect upon transfer characteristics, with stepped down fixed AC supply with an AC ammeter to read load current IL.

Scope of Study:

 ? To study input-output characteristic of a magnetic amplifier.

 ? Study of Feed back control characteristics.

 ? Study of Series feedback of amplifier

 ? Effect of Parallel feedback of amplifier. 

Technical Specifications:

 ? Two saturable reactors in one frame.

 ? Two Rectifiers.

 ? Fixed Resistive load.

 ? DC bias voltage.

 ? One potentiometer.

 ? Two digital meters.

 ? IC regulated power supply for complete circuitry.

 ? 220V ±10%, 50Hz mains operated.

 ? User's Manual with patch cords.

Insif Products

Our Related Product

Lab Plasticware
Biology
Chemistry
Civil & Survey
Pharmacy Lab Equipments
Insif India has regular exports to the following countries: India, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma/ Myanmar, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia, Comoros, Congo, Congo, Costa Rica, Cote d'Ivoire/Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Finland, France, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakstan, Kenya (Nairobi), Kiribati, Korea, North, Korea, South, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Portugal, Qatar, Romania, Russia, Rwanda (Kigali), Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Tanzania, Thailand, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, United Arab Emirates (Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe