Model No:RAC-2502
It consists of refrigeration cycle of domestic refrigerator, it consists a hermetically sealed compressor, air-cooled condenser, capillary tube and a natural convection type evaporator. The evaporator is fitted with a small heater to simulate different load conditions various measurements are provided so that power consumption, COP, theoretical and actual refrigerating effects refrigerant flow rate and effect of door opening on power consumption can be studied and also students can visualize automatic operation of unit using a thermostat.
It consists of refrigeration cycle of domestic refrigerator, it consists a hermetically sealed compressor, air-cooled condenser, capillary tube and a natural convection type evaporator. The evaporator is fitted with a small heater to simulate different load conditions various measurements are provided so that power consumption, COP, theoretical and actual refrigerating effects refrigerant flow rate and effect of door opening on power consumption can be studied and also students can visualize automatic operation of unit using a thermostat.
1. Compressor - Kirioskar make having capacity of approx. 1/25 ton of refrigeration.
2. Air - cooled condenser with natural convection airflow.
3. Capillary tube of matched length as expansion device.
4. Evaporator coil with an electric heater inside insulation on all side.
5. Measurement
a) Energymeter Tore compressor input power measurement.
b) Pressure gauge for condensing and evaporating pressure.
c) Flow meter for liquid refrigerant flow
d) Digital Temperature indicator for measurement of temperature
6. Safety & Controls a) High & low pressure cutout. b) Thermostat.
7. Floor space of 2m x 1m.onnection